Fiberglass Shelter: Model PBF
   
Applications
bulletChemical Storage
bulletChlorination Equipment
bulletMonitoring Equipment
bulletGenerators
bulletSafety Showers
bulletPumps
bulletLift Stations
bulletField Instruments
bulletElectronic Equipment
bulletPollution Control/Monitoring Equipment
  
Features
bulletGas tight gasketed door with safety chain
bulletGas tight observation window on door
bulletLifting eyes for field installation
bulletConstruction to withstand 90 mph wind load
bulletPitched roof to withstand 15 lbs./sq. ft. snow load
  
Standard Equipment
bulletContinuous stainless steel hinge
bulletAll stainless hardware
bulletPredrilled mounting flange
bulletMaintenance-free gel coat finish
Options Available
bulletAny non-standard power supply
bulletMounting, wiring, and piping of any type of equipment needed
bulletMotor starters, magnetic or manual
bulletCircuit breaker lighting distribution panels
bulletHigh temperature safety override
bulletExterior/Interior lighting
bulletSteel, wood, or fiberglass floor
bulletInsulation with several "R" values
bulletSpecial color
bulletSpecial holes or plumbing connections
bulletAlarm lights, horns, and silencing equipment
bulletTimer for exhaust fan
bulletPanic hardware/door closers
bulletFan canopy
bulletExhaust Fan
bulletHeater

Get a Quote

 

SPECIFICATIONS

1.0 SCOPE - This specification describes a Bevco House as manufactured by Bevco Engineering Company, Inc., W222N5739 Miller Way, Sussex, WI 53089. 

2.0 DESCRIPTION - The house shall be completely assembled, ready to install, and capable of housing any equipment as shown on the drawings. The Bevco House shall be model PBF and shall be supplied with all components factory mounted. 

3.0 DESIGN - The house shall be a one-piece molded fiberglass, reinforced polyester (FRP) construction with minimum wall, door, and roof thickness of 1/4". Units with cemented or bolted end caps will not be accepted. All materials of construction are to be ultraviolet resistant, and the finished house, when installed in accordance with the manufacturer's instructions, shall withstand 90 mph winds and a 15 lb./sq. ft. snow load. The 36"x 6'6" door shall have corrosion resistant hardware and the door shall be provided with a 17"x 17" shatterproof window. The house shall be designated hieght and width as per order x 7' high at the peak and shall be shipped factory assembled. Included shall be removable lifting eyes and sufficient gasket and mounting flanges for direct setting on concrete slab. 

4.0 COMPONENTS - The house shall have the following components factory mounted. 

4.1 MOUNTING HARDWARE - All mounting hardware shall be made of stainless steel or other corrosion resistant metal.