Fiberglass Shelter: Model ECS-F
  
Applications
Chemical Storage
Chlorination Equipment
Monitoring Equipment
Generators
Safety Showers
Pumps
Lift Stations
Field Instruments
Electronic Equipment
Pollution Control/Monitoring Equipment
  
Standard Equipment
One exhaust fan providing complete air change every minute
Automatic-manual selector switch, externally mounted and interlocked for automatic operation of the exhaust fan and light when door is opened
Door actuated microswitch for fan and light
Main electrical panel provided on the wall with the following equipment wired and mounted on the panel
Safety switch, 2 pole fused for 30 amps,120 volt 60 cycle, single phase
Duplex electrical receptacle
PVC light fixture(s) with covered bulb
Heater, with thermostat appropriately sized for each house

 

Features
Gas tight gasketed door with safety chain
Gas tight observation window on door
Motorized intake louver for ventilation with bug screens
Lifting eyes for field installation
Construction to withstand 150 mph wind load
Pitched roof to withstand 30 lbs./sq. ft. snow load
Large sub-panel with extra space for field mounting of accessories
   
Options Available
Any non-standard power supply
Mounting, wiring, and piping of any type of equipment needed
Motor starters, magnetic or manual
Circuit breaker lighting distribution panels
High temperature safety override
Exterior/Interior lighting
Steel, wood, or fiberglass floor
Special color
Special holes, or plumbing connections
Alarm lights, horns, and silencing equipment
Timer for exhaust fan
Panic hardware/door closers
Fan canopy
Special lighting
Special heating/cooling
  

Get a Quote

Download all of the AutoCAD drawings for  ECS buildings.
Click Here

For individual drawing files, see comparison chart below.

 

Model No. Width Length Height Weight Autocad Drawing
ECS-F64 6'-0" 4'-0" 7'-0" 420 lbs. sd-176.exe
ECS-F66 6'-0" 6'-0" 7'-0" 515 lbs. sd-177.exe
ECS-F68 6'-0" 8'-0" 7'-0" 610 lbs. sd-178.exe
ECS-F610 6'-0" 10'-0" 7'-0" 710 lbs. sd-184.exe
ECS-F612 6'-0" 12'-0" 7'-0" 875 lbs. sd-185.exe
ECS-F614 6'-0" 14'-0" 7'-0" 1100 lbs. sd-186.exe
ECS-F84 7'-6" 4'-0" 7'-0" 525 lbs. sd-224.exe
ECS-F86 7'-6" 6'-0" 7'-0" 630 lbs. sd-179.exe
ECS-F88 7'-6" 8'-0" 7'-0" 715 lbs. sd-180.exe
ECS-F810 7'-6" 10'-0" 7'-0" 775 lbs. sd-181.exe
ECS-F812 7'-6" 12'-0" 7'-0" 835 lbs. sd-182.exe
ECS-F814 7'-6" 14'-0" 7'-0" 895 lbs. sd-183.exe
   
AutoCAD® version 14 or later is required to open the files from this site.

SPECIFICATIONS

1.0 SCOPE - This specification describes a Bevco House as manufactured by Bevco Engineering Company, Inc., W222N5739 Miller Way, Sussex, WI 53089. 

2.0 DESCRIPTION - The house shall be completely assembled, ready to install, and capable of housing any equipment as shown on the drawings. The Bevco House shall be model ECS-F and shall be supplied with all components factory mounted and wired. 

3.0 DESIGN - The house shall be a one piece molded fiberglass reinforced polyester (FRP) construction with minimum wall, door, and roof thickness of 1". Units with cemented or bolted end caps will not be accepted. The house shall have a minimum of insulation to maintain a rating of "R" 7.2. All materials are to be ultraviolet resistant and the finished house, when installed in accordance with the manufacturer's instructions, shall withstand 150 mph winds, and a 30 lb./sq. ft. snow load. The 36"x 6'6" door shall have corrosion resistant hardware, and the door shall be provided with a 17"x 17" shatterproof window. The house shall be sized width and lenght to order x 7' high at the peak, and shall be shipped factory assembled and wired. Included shall be removable lifting eyes and sufficient gasket and mounting flanges for direct setting on concrete slab. 

4.0 COMPONENTS - The house shall have the following components factory mounted and wired in non-conductive, non-corrosive electrical conduit boxes, and fittings. 

4.1 ELECTRICAL FIXTURES - The following fixtures shall be provided: PVC light fixture(s) with covered bulb. Exterior mounted weatherproof automatic manual selector switch interlocked with a door operated micro switch to operate the fan and lights either manually or automatically when the door is opened. A 2 pole 120/60/1, fused safety switch of sufficient size to handle the electrical accessories. Duplex receptacle(s) in PVC weatherproof enclosure. 

4.2 EXHAUST FAN AND INTAKE LOUVERS - An exhaust fan shall be provided with gravity type louvers capable of providing complete air change every minute. Intake air shall come in through screened motorized intake louver of sufficient size to allow the specified air change. 

4.3 HEATER AND THERMOSTAT - A heater and adjustable thermostat with sealed contacts of sufficient size shall be provided.

 

Model ECS-F  |  Model 7521-F  |  Model 7521-S
Model 7523-F  |  Model 7523-S  |  Model PBF | Clamshell